Fixed point mixing station
Fixed point mixing station
Fixed-point mixing units are particularly suitable in situations where the heating system requires a constant temperature, regardless of external weather conditions. For example, they are the ideal choice for heating plants that supply a low-temperature circuit such as underfloor heating.
They stand out for their simplicity and reliability, offering an effective solution for heat management.
Documentation
Technical features
Description
Pre-assembled pump group for fixed point regulation and circulation of mixed fluid. It allows the circulation of the thermal fluid, coming from the primary circuit, by keeping the temperature at a pre-set value (fixed point) through the help of a mixing valve with thermostatic element.
It is used in heating systems in general and radiant panel systems.
The group is composed of a pump, thermostatic mixing valve, flow LCD thermometers, manual air vent, fittings for secondary distribution manifolds. The group can be installed with the secondary distribution manifolds on the right or the left.
It is used in heating systems in general and radiant panel systems.
The group is composed of a pump, thermostatic mixing valve, flow LCD thermometers, manual air vent, fittings for secondary distribution manifolds. The group can be installed with the secondary distribution manifolds on the right or the left.
Benefits
- Reversibility: thanks to the presence of a thermometer also on the rear side, the group can be easily inverted from right to left by fully reversing it.
- Flexibility of installation. The group can be installed on wall, in box or recessed.
- Monobloc structure. The thermostatic mixing valve and the instrument holder fitting, equipped with air vent and thermometers, are designed as monobloc structure. The installation is therefore immediate and points of possible leakage are reduced to a minimum.
- Anti-tamper device. The device, placed within the mixing valve knob, avoids undesired variations of the setting.
- Fast fittings. The provided fittings are equipped with O-Ring and flat gasket to make the installation faster, avoiding the use of other sealing systems like hemp or teflon tapes.
- Instrument holder fitting. Equipped with manual air vent, double LCD thermometer (on front and rear side) to check the temperature of the mixed water supplied to the system.
- Compact installation: the 75 mm centre distance of the primary side, the 211 mm centre distance to the secondary manifold and the 130 mm pump make the installation very compact.
Applications
-
T. max
- 5-90°C
-
Max. pressure
- 10 bar
-
T. max
- 5-90°C
-
Max. pressure
- 10 bar
-
T. max
- 5-90°C
-
Max. pressure
- 10 bar